| Processor |
| Number of
processors |
One to 14 |
| Architecture |
Superscalar
SPARC Version 9, UltraSPARC |
| CPU MHz |
250 or 336 |
| Cache per
processor |
Primary:
16-KB instruction, and 16-KB data on chip
Secondary: 1 MB or 4 MB external cache |
| CPU interface |
One to 14,
128-bit Ultra Port Architecture (UPA) slots |
| System
Boards |
| Number of
boards |
Maximum of
eight boards per system; minimum configuration requires one
CPU/Memory board and one I/O board |
| CPU/Memory
board |
Holds up
to two processors and 16 memory SIMM slots |
| SBus I/O
board |
Offers two
SBus channels, three SBus slots, SunFastEthernetTM,
fast/wide SCSI, two fibre channel sockets |
| SBus Graphics
I/O board |
Offers one
SBus channel, two SBus slots, one UPA slot for Creator and Creator3D
graphics, SunFastEthernet, fast/wide SCSI, two FC-AL sockets |
| PCI I/O board |
Offers four
PCI channels, two PCI slots, SunFastEthernet, fast/wide SCSI |
| Main
Memory |
256-MB
to 14-GB memory capacity per system
256-MB and 1-GB memory expansion options (each a group of 8
SIMMs)
Up to two memory expansion options per board |
| Standard
Interfaces |
| Serial |
Two RS-232/423
ports on clock board |
| SBus |
64-bit data
bus width, 25 MHz |
| PCI |
64-bit data
bus width, 66 MHz |
| Keyboard
and mouse port |
One per system |
| Ethernet |
10/100 Mb/sec
twisted pair standard (10-BaseT and 100-BaseT) or MII transceiver
per I/O board |
| SCSI |
20-MB/sec
fast/wide SCSI-2 (synchronous) per I/O board |
| FC-AL |
Two sockets
(100 MB/sec) per SBus I/O board |
| Internal
Mass Storage |
| Disk |
Maximum four
disk boards with two 3.5-in. SCSI-2 disk drives, 1.0-in. form
factor (2.1-GB formatted) |
| Tape |
Optional
12- to 24-GB DDS3 tape drive, 14-GB 8mm tape drive, or 2.5-GB
.25-in. tape drive |
| CD-ROM |
SunCDTM
12 drive standard |
| External
Mass Storage |
| Disk |
SPARCstorageTM
Array Model 100 Series (maximum thirty 2.1-GB or 4.2-GB fast/wide
SCSI-2 disks), SPARCstorage MultiPack (up to 54.6 GB using 2.1-GB,
4.2-GB, or 9.1-GB drives), SPARCstorage Array Model 200 RSMTM
Series (up to 382 MB of hot-swap 4.2-GB or 9.1-GB drives, and
redundant power and cooling), RSM Array 2000 (up to 318-GB of
fully redundant, mission-critical hardware RAID using 4.2-GB
or 9.1-GB drives) |
| Tape |
Multi-tape
backup tray, supporting up to four 72- to 144-GB 4mm DDS3 autoloaders,
14-GB 8mm tape drives, or 20- to 40-GB SPARCstorage DLTTM
4000, 140-GB SPARCstorage Library, 400-GB SPARCstorage Library |
| Console
Options |
| Monitor |
17- or 20-in
color monitor |
| Frame buffer |
TurboGXTM,
TurboGXplus, Creator or Creator3D frame buffer |
| SBus
Options |
| SunFastEthernet
adapter, SunATMTM adapter, SBus quad
Ethernet controller, differential fast/wide intelligent SCSI-2
SBus (DWIS/S), single-ended fast/wide intelligent SCSI-2 SBus
(SWIS/S) host adaptor, HSI, Token Ring interface, FDDI, fast
SCSI-2/buffered Ethernet, fast differential SCSI-2/buffered
Ethernet, fibre channel |
| PCI
Options |
| High-speed
serial interface, FDDI, SunFastEthernet, fast/wide SCSI |
| Power
Supplies |
Up
to four 300-watt system power supplies
One power supply required per two sytems boards
One 184-watt peripheral power supply
Fully redundant power and cooling available on this system |
| Software |
| Operating
system |
Solaris 2
operating environment |
| Languages |
C, C++, Pascal,
FORTRAN, JavaTM |
| Networking |
ONCTM,
NFSTM, TCP/IP, SunNetTM
OSI, MHS, X.25, DCE, NetWare |
| Windowing
system |
OpenWindowsTM
Version 3 optional |
| System monitoring |
Solstice
SyMON |
| System and
network management software |
Solstice
SunNet ManagerTM, Networker for SolarisTM,
Solstice DiskSuiteTM, SPARCstorage
Volume Manager |
| IBM/DEC connectivity |
SunLinkTM
connectivity products |
| Environment |
| AC power |
200-240 VAC,
47-63 Hz, 32 A |
| Operating |
5° C
to 35° C (41° F to 95° F) 20% to 80% relative
humidity, noncondensing |
| Nonoperating |
-20°
C to 60° C (-4° F to 140° F) 5% to 93% relative
humidity, noncondensing |
| Regulations
- meets or exceeds the following: |
| Safety |
UL 1950,
CSA 950, TUV EN60950, CB Scheme (Nordic Deviations) |
| RFI/EMI |
FCC Class
A, DOC Class A, EN55022 Class A, VCCI Class 1 |
| Immunity |
EN50082-1
|
| Harmonics |
EN61000-3-2
|
| Dimension
& Weight |
| Height |
143 cm (56
in.) |
| Width |
77 cm (30
in.) |
| Depth |
99 cm (39
in.) |
| Weight, main
cabinet |
360 kg (800
lb.) approx. |
| Power cord |
4.6 m (15
ft.) |
| Upgrades |
Chassis-level
upgrades are available for SPARCserver 1000/1000E, SPARCcenter
2000/2000E, and SPARCserver 690 servers.
Board upgrades available from SPARCserver 1000/1000E and SPARCcenter
2000/2000E. |