| Processors:
|
| Number
of Processors, Clock Rate |
4
to 64
250, 336, or 400 MHz |
| Architecture |
Superscalar
SPARCTM Version 9, UltraSPARCTM
processors |
| Cache
per processor |
Primary:
16-KB instruction, and 16-KB data on chip; Secondary: 4-MB
external cache |
| CPU
interface |
64-bit
Ultra Port Architecture (UPA) |
| System
Boards |
| Maximum
of 16 boards per Enterprise 10000 server; minimum configuration
is one system board, each holding up to four processors, up to four
SBus cards or two PCI cards, and a memory module with four banks
of eight SIMMS each |
| Main
Memory |
2-GB
to 64-GB memory capacity per system
256-MB and 1-GB memory expansion options (8 SIMMs each)
Up to four memory expansion options per system board |
| Standard
Interfaces |
| SBus
|
64-bit
data bus width, 25 MHz |
| PCI
|
32-bit
or 64-bit data bus width, 33 MHz or 66 MHz |
| Mass
Storage |
| Disk
Arrays |
Sun
StorEdgeTM A7000 (capacity up to 20 TB)
Sun StorEdgeTM A5000 FC-AL array (capacity
up to 10 TB)
Sun StorEdgeTM A3500 (capacity up to 5
TB) |
| Disk
tray |
Sun
StorEdgeTM D1000 (capacity up to 2 TB)
|
| S-Bus Options |
- SunFastEthernetTM
adapter
- SunATMTM
adapter
- SBus
quad Ethernet controller
- Differential
fast/wide intelligent SCSI-2 SBus (DWIS/S)
- UltraSCSI
(UDWIS/S)
- Single-ended
fast/wide intelligent SCSI-2 SBus (SWIS/S) host adaptor
- SunHSITM
- Token
Ring interface
- SunFDDITM
(SAS and DAS)
- Fibre
channel
|
| Power Supplies |
| Fully
redundant power and cooling standard with this system. |
| RAS
Features |
- On-line hot swap of boards, power,
and cooling components
- Fault-tolerant power and cooling
- Redundant AC line cords and breakers
- Monitoring tools
- Automatic system recovery
- Domains
- ECC on memory and Interconnect
- Complete parity checking
- Environmental monitoring
- Remote console support
- Redundant consoles
- Interconnect data path resiliency
- Interconnect address path resiliency
- Redundant "housekeeping" functions
- Redundant option for all hardware
components
|